Skip to main content
DCS Global

Oil & Gas

Infrastructure for Oil & Gas Environments

Upstream, midstream, and downstream oil and gas operations depend on control room infrastructure, SCADA power continuity, and field electrical systems that must perform reliably in hazardous area classifications, remote locations, and harsh environmental conditions. DCS Global supports oil and gas operators with critical power, hazardous area electrical infrastructure, structured cabling, and commissioning — with the permit-to-work discipline and PSM documentation awareness that process industry environments require.

Infrastructure Challenges

What Oil & Gas Organizations Face

Hazardous area classifications (Class I Division 1/2, Zone 0/1/2) impose equipment selection and installation requirements that standard commercial electrical contractors are not qualified to satisfy

SCADA and safety instrumented system (SIS) power continuity requirements where control system failures create safety and environmental liability — not just operational downtime

Remote and harsh deployment environments — offshore platforms, pipeline compressor stations, and remote production facilities — with extreme temperatures, humidity, and physical access constraints

Process Safety Management (PSM) and Management of Change (MOC) documentation requirements that impose obligations on infrastructure modifications in covered process facilities

Aging control room and field electrical infrastructure that has been deferred through commodity price cycles and now represents both operational and safety risk

OT/IT convergence and ICS security requirements creating new physical infrastructure needs at the boundary between process control networks and enterprise IT

How DCS Global Helps

Relevant DCS Capabilities

Not sure where to start?

A DCS Global engineer can assess your current infrastructure and identify the highest-priority gaps.

Solution Mapping

Infrastructure Need → DCS Solution

The most relevant DCS solutions for Oil & Gas organizations — with context on why each matters in this environment.

Regulatory Context

Compliance & Requirements

Oil and gas infrastructure operates within a framework of process safety and regulatory requirements. Facilities covered by OSHA's Process Safety Management (PSM) standard (29 CFR 1910.119) are subject to Management of Change (MOC) requirements that impose documentation obligations on infrastructure modifications. Electrical work in classified hazardous areas must comply with NFPA 70 (National Electrical Code) Articles 500–516 and may be subject to additional requirements from API standards and equipment manufacturer specifications. Offshore facilities are subject to BSEE (Bureau of Safety and Environmental Enforcement) regulations and USCG requirements. DCS Global does not hold process safety certifications, but our project teams are experienced in executing infrastructure work within PSM frameworks — following permit-to-work procedures, coordinating with facility safety officers, and delivering documentation that supports MOC and PSM requirements. Specific requirements vary by facility type, regulatory jurisdiction, and process; DCS Global works with the client's safety, engineering, and facilities teams to understand applicable requirements before project execution.

Full-Lifecycle Delivery

Oil and gas infrastructure has a lifecycle defined by process safety obligations that don't end at commissioning. MOC documentation must be maintained for the life of the facility. PSSR records become part of the permanent process safety file. Preventive maintenance on UPS and control room electrical systems must be documented to support PSM program requirements. DCS Global supports oil and gas infrastructure from initial assessment through commissioning and into ongoing maintenance — maintaining the PSM documentation trail and permit-to-work discipline that process industry operations require at every stage.

AssessDesignSourceInstallTestCommissionDocumentHand OverSupport

Common Questions

Frequently Asked Questions

DCS Global project managers work within the facility's permit-to-work system — obtaining required permits, coordinating with the facility safety officer, and following hot work, confined space, and lockout/tagout procedures as applicable. Work plans are developed in advance and reviewed with the facility's safety and operations teams before execution begins. Personnel working in oil and gas facilities follow the facility's safety induction, PPE requirements, and site-specific safety rules.

Electrical installations in classified hazardous areas (Class I Division 1/2 or Zone 0/1/2) require equipment that is listed or approved for the specific hazardous location classification — explosion-proof, intrinsically safe, or purged and pressurized as appropriate. Installation methods must comply with NEC Articles 500–516 and applicable API standards. Documentation should include equipment classification records, installation inspection records, and as-built drawings that support ongoing maintenance and PSM requirements.

DCS Global can provide documentation packages that support PSM Management of Change (MOC) requirements, including pre-startup safety review (PSSR) documentation, as-built drawings, equipment data sheets, and installation records. Specific documentation requirements are determined by the facility's PSM program and the nature of the infrastructure modification. DCS Global works with the facility's PSM coordinator to understand applicable documentation requirements before project execution.

Aging control room infrastructure should be assessed for equipment age, maintenance history, and condition against current load requirements and safety standards. UPS and battery systems without recent load test records represent unquantified risk for SCADA and SIS availability. Electrical distribution systems that have not been maintained or tested to current standards may represent both operational and safety risk. A condition assessment provides the basis for a prioritized upgrade program.

DCS Global has experience supporting infrastructure projects in remote and challenging environments, including offshore and remote production facilities. Remote site projects require additional logistics planning — material staging, personnel mobilization, and access coordination — that DCS Global project managers incorporate into project planning. Specific capabilities for offshore projects depend on the platform type, location, and access requirements.

OSHA 29 CFR 1910.119 (Process Safety Management of Highly Hazardous Chemicals) applies to facilities that process chemicals above threshold quantities. PSM requires covered facilities to implement Management of Change (MOC) procedures for any modification to process equipment, instrumentation, or supporting infrastructure — including electrical and control system infrastructure. Infrastructure contractors working in PSM-covered facilities must submit MOC documentation before beginning work, participate in Pre-Startup Safety Reviews (PSSRs) for affected systems, and comply with the facility's permit-to-work system. DCS Global project managers are experienced in PSM MOC documentation requirements and can prepare the required change packages for review by the facility's process safety team.

NEC Article 500 classifies locations where flammable gases, vapors, or dusts may be present into Classes (I for gases/vapors, II for dusts, III for fibers) and Divisions (1 for normally present, 2 for abnormally present). Oil and gas facilities typically include Class I, Division 1 and Division 2 locations in areas where hydrocarbon vapors may accumulate. Electrical equipment installed in classified locations must be rated and listed for the specific classification — standard commercial electrical equipment cannot be used. This affects UPS systems, PDUs, lighting, and any electrical infrastructure installed in or near classified areas. DCS Global works with the facility's electrical engineer to verify area classifications before specifying equipment and ensures all installations comply with the applicable NEC Article 500 requirements and the facility's electrical area classification drawings.

Get Started

Planning an Oil & Gas Infrastructure Project?

Talk with DCS Global about your critical power, hazardous area electrical, or commissioning requirements. We work with oil and gas operations and facilities teams to deliver infrastructure with the safety discipline and PSM documentation that process industry environments require.